Reference Manual
00809-0100-4530, Rev BA
July 2009
G-3
Rosemount 5300 Series
DB_REG_2_FLOAT 49 If the register contains a float value, it should be displayed here
DB_REG_2_INT_DEC 50 If the register contains a DWORD value, and dec is chosen, it
should be displayed here
DB_REG_3_TYPE 51 Register type
DB_REG_3_FLOAT 52 If the register contains a float value, it should be displayed here
DB_REG_3_INT_DEC 53 If the register contains a DWORD value, and dec is chosen, it
should be displayed here
DB_REG_4_TYPE 54 Register type
DB_REG_4_FLOAT 55 If the register contains a float value, it should be displayed here
DB_REG_4_INT_DEC 56 If the register contains a DWORD value, and dec is chosen, it
should be displayed here
DB_REG_5_TYPE 57 Register type
DB_REG_5_FLOAT 58 If the register contains a float value, it should be displayed here
DB_REG_5_INT_DEC 59 If the register contains a DWORD value, and dec is chosen, it
should be displayed here
DB_REG_6_TYPE 60 Register type
DB_REG_6_FLOAT 61 If the register contains a float value, it should be displayed here
DB_REG_6_INT_DEC 62 If the register contains a DWORD value, and dec is chosen, it
should be displayed here
DB_REG_7_TYPE 63 Register type
DB_REG_7_FLOAT 64 If the register contains a float value, it should be displayed here
DB_REG_7_INT_DEC 65 If the register contains a DWORD value, and dec is chosen, it
should be displayed here
DB_REG_8_TYPE 66 Register type
DB_REG_8_FLOAT 67 If the register contains a float value, it should be displayed here
DB_REG_8_INT_DEC 68 If the register contains a DWORD value, and dec is chosen, it
should be displayed here
DB_REG_9_TYPE 69 Register type
DB_REG_9_FLOAT 70 If the register contains a float value, it should be displayed here
DB_REG_9_INT_DEC 71 If the register contains a DWORD value, and dec is chosen, it
should be displayed here
DB_REG_10_TYPE 72 Register type
DB_REG_10_FLOAT 73 If the register contains a float value, it should be displayed here
DB_REG_10_INT_DEC 74 If the register contains a DWORD value, and dec is chosen, it
should be displayed here
RM_COMMAND 75 Used to set what will be read or write from a secondary master.
RM_DATA 76 Data read/write from secondary master.
RM_STATUS 77 Status read by a secondary master.
Parameter
Index
Number
Description