Emerson Process Management ROSEMOUNT 5300 Manual de usuario Pagina 119

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 324
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 118
Reference Manual
00809-0100-4530, Rev BA
July 2009
5-47
Rosemount 5300 Series
HART MULTI-DROP
CONFIGURATION
The 5300 transmitter can be run in multidrop mode. In the multidrop mode
each transmitter has a unique HART address.
Figure 5-19. Multidrop
connection
The poll address can be changed by using a 375 Field Communicator or by
using the Rosemount Radar Master software.
To change the poll address using a 375 Field Communicator, choose HART
command [2, 2, 4, 1].
To change the poll address using the Rosemount Radar Master (RRM)
software:
1. Choose the Setup>General option.
2. Select the Communication tab.
3. Set the desired address (between 1 and 15 for multidrop operation).
4. Click the Store button to save the new address.
Vista de pagina 118
1 2 ... 114 115 116 117 118 119 120 121 122 123 124 ... 323 324

Comentarios a estos manuales

Sin comentarios